LabReport (#998)

Name
5.5.2025
Sample Name
Willies Remedy Tropical Citrus
Sample Matrix
Beverage
Product Type
cannabis
Lab Name
Fina Analytics
Matching Name
5.5.2025 Willies Remedy Tropical Citrus Beverage
Category
5mg - 750mL Bottle
Type
png
State
Processed
Additional Data

Extraction Date: 2025-04-30

Expiry Date:

Delta-9 %: 0.01112

THC-A %: 0

Total THC %: 0.01112

D9/THC-A %: 0.01112

Debug Data
Null
Markdown Content

Certificate of Analysis
1 of 1

# Willies Remedy Tropical Citrus

- **Sample ID:** 505E1005.05
- **Type:** Finished Product
- **Matrix:** Beverage
- **Unit Size:** 46.62g

- **Batch ID:** BTL252804
- **Collected:** 4/30/2025
- **Received:** 5/5/2025
- **Completed:** 5/5/2025

- **Client:** Midwest Extraction Services
- **Phone:** 507-214-3550
- **Lic. #:** 20211071

| Total THC | Total THC | Total Cannabinoids |
|-----------|-----------|--------------------|
| 5.19mg/unit | 0.0% | 0.02% |

## Cannabinoids by HPLC-UV

| Analyte | LOQ (mg/mL) | Results (%) | Results (mg/unit) |
| ------- | ----------- | ----------- | ----------------- |
| CBDVA | --- | 0.00000 | 0.00 |
| CBDV | --- | 0.00000 | 0.00 |
| CBDA | --- | 0.00000 | 0.00 |
| CBGA | --- | 0.00000 | 0.00 |
| CBG | 0.0003 | 0.00471 | 2.20 |
| CBD | 0.0003 | 0.00474 | 2.21 |
| THCV | --- | 0.00000 | 0.00 |
| THCVA | --- | 0.00000 | 0.00 |
| CBN | 0.0003 | 0.00029 | 0.14 |
| d9-THC | 0.0003 | 0.01112 | 5.19 |
| d8-THC | 0.0003 | 0.00000 | 0.00 |
| CBC | --- | 0.00000 | 0.00 |
| THCA | --- | 0.00000 | 0.00 |
| CBCA | --- | 0.00000 | 0.00 |
| Total | | 0.021 | |

LOQ = Limit of Quantification; Total THC = d9-THC + (0.877 x THCA); Total CBD = CBD + (0.877 x CBDA)

----

**Analyst:** Johanna Holloway
**Date:** 05/05/2025

!Willies Remedy Tropical Citrus

----

2300 Brown Ave ste 130,
Waseca, MN 56093
(507)-214-3550 #5
analytics@finaelabs.co

----

This item has been tested by Fina Analytics and the results relate only to the sample tested. Fina Analytics makes no claim as to the efficacy, safety or other risks associated with detected or non-detected amounts of substances reported herein. The reported result is based on the sample weight. This Certificate of Analysis shall not be reproduced except in full, without approval of Fina Analytics. Validated testing methodologies with an ISO IEC 17025:2017 accredited quality system was used when an (*) is present on the Certificate of Analysis. Measurement of uncertainty is not used for pass/fail conditions but available upon request.